TECHNICAL DATASHEET Medical AC-DC Adapter MDS-030AAC Series / MDS-030AAC□ 030AAC Highlights & Features • • • • • • • • • MDS-030AAC05, 12, 15, 24 Meet Efficiency Level VI Safety Approvals to IEC 60601-1 3.1rd ed. & IEC 62368-1 Compliant with IEC 60601-1-2 4th Ed. Requirements Meets Limited Power Source (LPS) requirements Low touch current. Suitable for type BF applications Detachable AC plug with multiple country options IP22 ingress protection rating 2 × MOPP isolation 500K hours MTBF Safety Standards CB Certified for worldwide use Model Number: MDS-030AAC☐ Unit Weight: 150 grams Dimensions (W × L × H): 53.5 × 88.0 × 27.5 mm 2.11 × 3.46 × 1.08 inch General Description The MDS series of external power supply comes with universal AC input at 85 Vac to 264 Vac. Other features include low touch current, risk management report available and the electric shock protection comply with 2 × MOPP. The MDS series is certified for EMC standards according to EN/BS EN 55011 for industrial, scientific and medical (ISM) radio-frequency equipment and EN/BS EN 55032 for Information Technology Equipment (ITE) radio-frequency equipment. In addition, only recognized Japanese capacitors are used. The MDS series come with both medical and ITE safety approvals including UL/cUL and IEC 60950-1 CB certification as a Limited Power Source (LPS), and CCC approval. Designs are fully compliant with RoHS Directive for environmental protection. Model Information Medical AC-DC Adapter Model Number MDS-030AAC05 Input Voltage Range Efficiency Level 85-264Vac Level VI Rated Output Voltage 5 Vdc Rated Output Current 3A MDS-030AAC12 Level VI 12 Vdc 2A MDS-030AAC15 Level VI 15 Vdc 2A MDS-030AAC24 Level VI 24 Vdc 1.25 A Model Numbering MDS – 030 Delta Medical Power Supply Max wattage in the product series AAC Family Code  Output Voltage (Single Output)   1 Revision Code Revision Code2 - 05 for 5 V DC plug type and output cable length Country duck-head type - 12 for 12 V - 15 for 15 V A:2.1 x 5.5 x10mm DC plug B:2.1 x 5.5 x12mm DC plug - 24 for 24 V Both A & B are 1200mm cable length C:European; D:United Kingdom; A:China ; B:United States; E:Australia; G:Korea; H: India, J :Argentina ; K:Brazil; M:South Africa * MDS-030AAC15 BB is not available. 1 All parameters are specified at 25°C ambient unless otherwise indicated. www.DeltaPSU.com (October 2021, Rev.13) TECHNICAL DATASHEET Medical AC-DC Adapter MDS-030AAC Series / MDS-030AAC□ Specifications Model Number MDS-030AAC12 MDS-030AAC05 MDS-030AAC15 MDS-030AAC24 Input Ratings / Characteristics Nominal Input Voltage 100-240 Vac Input Voltage Range 85-264 Vac Nominal Input Frequency 50-60 Hz Input Frequency Range 47-63 Hz Input Current (max) Average Efficiency (min) 115 Vac 0.5 A 0.6 A 0.8 A 0.8 A 230 Vac 0.3 A 0.4 A 0.6 A 0.6A 115 Vac 81.4% 86.21% 87.0% 87.0% 0.1 W 0.1 W 0.1 W 230 Vac Standby Power (max) 115 Vac 0.1W 230 Vac Inrush Current (typ.) 60 A @ 115 Vac and 100 A @ 230 Vac Touch Current (max) 0.1 mA @ 264 Vac NC1), 0.3 mA @ 264 Vac SFC2) Output-PE (protective earth) leakage current for Type BF application (max) 0.1 mA @ 264 Vac NC1), 0.5 mA @ 264 Vac SFC2) 1) 2) NC: Normal condition SFC: Single fault condition Model Number MDS-030AAC12 MDS-030AAC05 MDS-030AAC15 MDS-030AAC24 Output Ratings / Characteristics Nominal Output Voltage 5 Vdc 12 Vdc 15 Vdc Output Total Regulation 24 Vdc ±6% Output Current 3A 2A 2A 1.25 A Output Power 15 W 24 W 30 W 30 W Line Regulation ±1% Load Regulation ±5% Ripple & Noise (max) 100 mVpk-pk @ Rated load 150 mVpk-pk @ Rated load 200 mVpk-pk @ Rated load 200 mVpk-pk @ Rated load Start-up Time (max) 3000 ms @ 115 Vac Hold-up Time (min) 10 ms @ 115 Vac Dynamic Response (Overshoot & Undershoot O/P Voltage) ±10% @ 50-100% load Capacitive load (max) 4700 uF *Periodic and Random Deviation. Ripple & Noise measurement circuit with 20 MHz BW PSU 5cm 0.47uF Ceramic 10uF Electrolytic Load Scope Test Fixture 2 All parameters are specified at 25°C ambient unless otherwise indicated. www.DeltaPSU.com (October 2021, Rev.13) TECHNICAL DATASHEET Medical AC-DC Adapter MDS-030AAC Series / MDS-030AAC□ Model Number MDS-030AAC05 MDS-030AAC12 MDS-030AAC15 MDS-030AAC24 Mechanical Case Chassis PC Case Cover PC Dimensions (W × L × H) 53.5 × 88.0 × 27.5 mm (2.11 × 3.46 × 1.08 in) Unit Weight 150 grams (5.3 ounces) Indicator NA Cooling System NA Terminal Input Detachable type AC plug Output Barrel type. Dimensions 2.1 × 5.5 × 10 mm (see page 5) Environment Surrounding Air Temperature Operating 0°C to +40°C Storage -40°C to +85°C Operating Humidity 5 - 95% RH (Non-Condensing) Operating Altitude 5,000 meters (16400 feet) Shock Test (Non-Operating) 50 G, 11 ms, 3 shocks for each direction Vibration (Non-Operating) 5-500 Hz, 2.09 Grms, 20 minute for each three axis Protections Overvoltage (max) 150%, Latch Mode Overload / Overcurrent (max) 250% of rated load current, Hiccup Mode, (Non-Latching, Auto-Recovery) Hiccup Mode, (Non-Latching, Auto-Recovery) Over Temperature Short Circuit Hiccup Mode, (Non-Latching, Auto-Recovery) Degree of Protection IP22 Protection Against Shock Class II Reliability Data MTBF (min) 3 500 K Hours based on Telecordia SR-332 (at 100 Vac, Max. load and 25°C Ambient) All parameters are specified at 25°C ambient unless otherwise indicated. www.DeltaPSU.com (October 2021, Rev.13) TECHNICAL DATASHEET Medical AC-DC Adapter MDS-030AAC Series / MDS-030AAC□ Model Number MDS-030AAC05 MDS-030AAC12 MDS-030AAC15 MDS-030AAC24 Safety Standards / Directives Medical Safety ITE Safety CE UKCA Galvanic Isolation IEC 60601-1 Edition 3.1 (2012), EN 60601-1 (2006) + A11 + A1 + A12, CAN/CSA-C22.2 NO. 60601-1:14, ANSI/AAMI ES 60601-1:2005/(R)2012 UL60601-1 (File No. E356265) IEC 60950-1 (Ed.2,2005), IEC 62368-1, GB4943.1-2011, GB 9254-2008, GB 17625.1-2003 UL 60950-1 (File No. E131881), LPS (Limited Power Source) In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU EN 60601-1: 2006 + A11: 2011 + A1: 2013 + A12: 2014 & EN 60601-1-2: 2015 In conformance with Electrical Equipment (Safety) Regulations 2016 and Electromagnetic Compatibility Regulations 2016, Medical Devices Regulations 2002(UK MDR 2002) Input to 4000 Vac Output EMC (Compliant with IEC 60601-1-2 4th Ed. Requirements) EMC / Emissions Harmonic Current Emissions EN/BS EN 55011,EN/BS EN 55032, FCC Title 47:Class B IEC61000-3-2 Immunity to Voltage Flicker IEC61000-3-3 Electrostatic Discharge IEC61000-4-2 Level 4 Criteria A1) Air Discharge: 15 kV Contact Discharge: 8 kV Radiated Field IEC61000-4-3 Criteria A1) 80MHz-2700MHz, 10 V/m AM modulation 385MHz-5785MHz, 28 V/m Pulse mode and other modulation Electrical Fast Transient / Burst IEC61000-4-4 Level 3 Criteria A1): 2 kV Surge IEC61000-4-5 Conducted IEC61000-4-6 Level 3 Criteria A1) Differential Mode3): 1 kV Level 2 Criteria A1) 150 kHz-80 MHz, 3 Vrms, 6 Vrms at ISM bands and Amateur radio bands Power Frequency Magnetic Fields IEC61000-4-8 Voltage Dips IEC61000-4-11 Criteria A1) Magnetic field strength 30 A/m Criteria A1) 0% UT, 0.5 cycle (10 ms) , 0o/45o/90o/135o/180o/225o/270o/315o/360o Criteria B2) 0% UT, 1 cycle (20 ms), 0o Criteria B2) 70% UT, 25 cycle (500 ms), 0o Criteria B2) 0% UT, 250 cycle (5000 ms), 0o 1) Criteria A: Normal performance within the specification limits 2) Criteria B: Output out of regulation, or shuts down during test. Automatically restore to normal operation after test. 3) Symmetrical: Differential mode (Line to line) 4 All parameters are specified at 25°C ambient unless otherwise indicated. www.DeltaPSU.com (October 2021, Rev.13) TECHNICAL DATASHEET Medical AC-DC Adapter MDS-030AAC Series / MDS-030AAC□ Block Diagram Dimensions W × L × H: 53.5 × 88.0 × 27.5 mm Note: The plug’s polarity is 5 All parameters are specified at 25°C ambient unless otherwise indicated. www.DeltaPSU.com (October 2021, Rev.13) TECHNICAL DATASHEET Medical AC-DC Adapter MDS-030AAC Series / MDS-030AAC□ Duck Head Type: 6 CN type US/JP type EU type UK type AU KR type IN type AR type BZ type SA type All parameters are specified at 25°C ambient unless otherwise indicated. www.DeltaPSU.com (October 2021, Rev.13) TECHNICAL DATASHEET Medical AC-DC Adapter MDS-030AAC Series / MDS-030AAC□ Functions Start-up Time The time required for the output voltage (Vo) to reach 90% of its set value, after the input AC voltage is applied. Rise Time The time required for the output voltage (Vo) to change from 10% to 90% of its steady state value. Hold-up Time Hold up time is the time when the AC input collapses and output voltage retains regulation for a certain period of time. The time required for the output to reach 95% of its set value, after the input voltage is removed.  Graph illustrating the Start-up Time, Rise Time, and Hold-up Time Inrush Current Dynamic Response Inrush current is the input current that occurs when the input voltage is first applied. For AC input voltages, the maximum peak value of inrush current will occur during the first half cycle of the applied AC voltage. This peak value decreases exponentially during subsequent cycles of AC voltage. The power supply output voltage will remain within ±3% of its steady state value, when subjected to a dynamic load change from 50 to 100% of its rated current. 7 All parameters are specified at 25°C ambient unless otherwise indicated. www.DeltaPSU.com (October 2021, Rev.13) TECHNICAL DATASHEET Medical AC-DC Adapter MDS-030AAC Series / MDS-030AAC□ Overload & Over current Protections Overvoltage Protection The power supply’s Overload (OLP) and Over current (OCP) Protections will be activated when output current is between 110% and 250% of IO (Max load). Upon such an occurrence, VO will start to drop. Once the power supply has reached its maximum power limit, the protection will be activated and the power supply will go into “Hiccup mode” (Auto-Recovery). The power supply will recover once the fault condition causing the OLP and OCP is removed and IO is back within the specified limit. The power supply’s overvoltage circuit will be activated when its internal feedback circuit fails. The output voltage shall not exceed its specifications defined on Page 3 under “Protections”. Power supply will latch off, and require removal/re-application of input AC voltage in order to restart. Over Temperature Protection As mentioned above, the power supply also has Over Temperature Protection (OTP). This is activated when the overload condition persists for an extended duration and the output current is below the overload trigger point but >100% load. In the event of a higher operating condition at 100% load, the power supply will run into OTP when the surrounding air temperature is higher than the operating temperature. When activated, the output voltage will go into hiccup mode until the input voltage is removed; then, reapplied, and the surrounding air temperature drops to its normal operating temperature. Additionally, if the IO is 110% for a prolong period of time (depending on the load), the Over Temperature Protection (OTP) will be activated due to high temperature on critical components. The power supply will then go into hiccup mode until the fault is removed; and, the input voltage is removed, then reapplied. Short Circuit Protection (Auto-Recovery) The power supply’s output OLP/OCP function also provides protection against short circuits. When a short circuit is applied, the output current will operate in “Hiccup mode”, as shown in the illustration in the OLP/OCP section on this page. The power supply will return to normal operation after the short circuit is removed. 8 All parameters are specified at 25°C ambient unless otherwise indicated. www.DeltaPSU.com (October 2021, Rev.13) TECHNICAL DATASHEET Medical AC-DC Adapter MDS-030AAC Series / MDS-030AAC□ Certificate Typically, the input current waveform is not sinusoidal due to the periodical peak charging of the input capacitor. In industrial environment, complying with EN 61000-3-2 is only necessary under special conditions. Complying to this standard can have some technical drawbacks, such as lower efficiency as well as some commercial aspects such as higher purchasing costs. Frequently, the user does not profit from fulfilling this standard, therefore, it is important to know whether it is mandatory to meet this standard for a specific application. In addition to a UL Total Certification Program (TCP) approved client laboratory for IEC62368-1. Delta also has participated UL Client Test Data Program (CDTP) for IEC 60601. Meet Level V Efficiency Requirement for MDS-030AAC07 Meet Level VI Efficiency Requirement for MDS-030AAC05, 12, 15, 24 Meets Limited Power Source (LPS) requirement Attention Delta provides all information in the datasheets on an “AS IS” basis and does not offer any kind of warranty through the information for using the product. In the event of any discrepancy between the information in the catalog and datasheets, the datasheets shall prevail (please refer to www.DeltaPSU.com for the latest datasheets information). Delta shall have no liability of indemnification for any claim or action arising from any error for the provided information in the datasheets. Customer shall take its responsibility for evaluation of using the product before placing an order with Delta. Delta reserves the right to make changes to the information described in the datasheets without notice. Manufacturer and Authorized Representatives Information Manufacturer Thailand Delta Electronics (Thailand) PCL. 909 Pattana 1 Rd., Muang, Samutprakarn, 10280 Thailand Taiwan Delta Electronics, Inc. 3 Tungyuan Road, Chungli Industrial Zone, Taoyuan County 32063, Taiwan Authorized Representatives The Netherlands Delta Greentech (Netherlands) B.V. Zandsteen 15, 2132 MZ Hoofddorp, The Netherlands 9 United Kingdom Delta Electronics Europe Limited 1 Redwood Court, Peel Park Campus, East Kilbride, Glasgow, G74 5PF, United Kingdom All parameters are specified at 25°C ambient unless otherwise indicated. www.DeltaPSU.com (October 2021, Rev.13)
ADP-168 K 价格&库存

很抱歉,暂时无法提供与“ADP-168 K”相匹配的价格&库存,您可以联系我们找货

免费人工找货